Emergency Lighting inspections, sales and service are available from Full Service Fire Protection for the Atlanta Metro Area. Emergency lighting and exit lighting is a requirement for most commercial and industrial facilities and a necessity for work place safety. The requirements under OSHA 1910.37 & NFPA 101 require that the lights be tested for 30 seconds monthly and 90 minutes annually. If your Emergency Lighting need new batteries or parts like bulbs, we can do all repairs or replacements at the time of the inspection. For new construction, we can assist you to develop and install a proper emergency lighting system for your office or workplace. We feature quality Lithonia Lighting systems.

Emergency Lighting Systems & Replacement Batteries

EMERGENCY & EXIT LIGHTING – General Requirements. Emergency and Exit Lighting Equipment is designed to provide illumination during power outages. Emergency lights illuminate paths during power outages. Illuminated exit signs identify safe exits. Full Service Fire Protection uses the National Fire Protection Association (NFPA) Standards NFPA 101 – Life Safety Code and NFPA 70 – National Electric Code as a guide for inspecting and maintaining emergency lighting equipment. Equipment owners are responsible to see that all Emergency Lighting and Exit Lightings is maintained, tested and inspected for proper operations.

Emergency lighting is required to be inspected at least monthly.

A monthly inspection is a “quick check” of the Emergency lighting fixture. For Emergency lighting, the following procedures must be performed for monthly inspections:

  • Check for physical damage to the exterior of the unit (test switch, pilot lamp, broken heads, etc.).
  • Verify that the AC Ready light is on.
  • Verify that the bulbs in the Exit Signs are illuminated.
  • Verify that the red or green diffuser on Exit Signs are not bleached, faded, burnt or cracked.
  • Verify that the lamps on Emergency Lights and Exit Signs equipped with a battery backup illuminate when the test switch is depressed (press and hold Test Switch for a minimum of 30 seconds)
  • Verify that the lamps on Emergency Lights are properly aligned and secure.

Monthly Inspection Record Keeping

At least monthly, the date the inspection was performed and the initials of the person performing the inspection shall be recorded.

Annual Test Of Emergency Lighting

Emergency Lights are required to be tested at least annually. The annual test includes the following:

  • Check for physical damage to the exterior of the unit (test switch, pilot lamp, broken heads, etc.)
  • Check the operation of the unit by exercising the test button
  • Open the unit and checking the tightness and cleanliness of battery terminals
  • Measure the battery “Float Voltage” with a DC Voltmeter to assure that the battery charger is functioning properly
  • Use a Battery Analyzer to perform a Battery Load Test (or Battery Burn Test as may be required by Local authority) to assure that the battery is functioning properly
  • Verify that all lamps are working properly
  • Replace defective parts as needed (batteries and bulbs)

Annual Test Record Keeping

Affix a label to all Emergency Lights that have been tested, indicating the date the test was conducted, the type of test conducted, and the name of the Inspector performing the work. In addition to the required Certification Label, document the location and type of all Emergency Lights tested. These Location Surveys are available to our customers. The Location Surveys can serve as proof of service for insurance underwriting purposes, for local Fire Code compliance, and can be used as a budgeting tool to forecast future service requirements.

 

Emergency Light Replacement Batteries

Power Rite Battery, PRB64
Exit & Emergency Light repacement battery.
6V, 4A size 2 3/4″x 4″x 1 7/8″

Power Rite Battery, PRB67
Exit & Emergency Light repacement battery.
6V, 7A size 6″x 3 3/4″x 1 3/8″

Brooks Power Rite Battery, BAT 446
Emergency Light Battery, 4V, 4.6A,
size  1 7/8″x 3 3/4″x 2 1/16″   replacement battery

Power Rite Battery, PRB612
Exit & Emergency Light repacement battery.
6V, 12A, size 6″x 3 3/4″x 2″

Brooks Power Rite Battery, BAT 620
Emergency Light Battery, 6V, 20A,
size 6 3/16″x 4 7/8″x 3 5/16″ replacement battery

Power Rite Battery, PRB623
Exit & Emergency Light repacement battery.
6V, 2.3A, size 1 13/16″ x 3″ x 1 7/16″

 

 

 

Emergency Light Replacement Bulbs

Emergency Lighting Replacement Bulb BT6
Replacement Bulb for emergency lighting, 145 V, 15 W, Candelabra Screw (15T6)

Emergency Lighting Replacement Bulb BT65S
Replacement Bulb for emergency lighting, 120 V, 20 W, Intermediate Screw (20T6.5)

Emergency Lighting Replacement Bulb BT914
Replacement Bulb for emergency lighting, 4 V, 3.6 W, Miniature Wedge (914)

Emergency Lighting Replacement Bulb BT47
Replacement Bulb for emergency lighting, 6.3 V, .9 W, Single Contract Bayonet (47T3.25)

Emergency Lighting Replacement Bulb BT65DC
Replacement Bulb for emergency lighting, 120 V, 20 W, Dbl. Contract Bayonet (20T6.5)

Emergency Lighting Replacement Bulb B7C7
Replacement Bulb for emergency lighting, 120 V, 7 W, Candelabra Screw (B7C7)
Similar to photo.

 

Service & Sales

Full Service Fire Protection is a locally owned and operated company dedicated to superior service. We have over 25 years experience in the Fire Protection Industry and we are full insured and bonded your protection. All of our fire service technicians are fully trained and certified in the State of Georgia and attend annual training to stay up to date on all fire protection systems. We stand behind all of our products and our goal is complete customer satisfaction.

  • Emergency Lighting Inspections
  • Emergency Lighting Installations
  • Exit Lighting
  • LED Exit Lights
  • LED Emergency Lights
  • Replacement Batteries
  • Replacement Bulbs

Amerex Fire Extinguisher Dealer

Ansul Fire Extinguisher Dealer

Badger Fire Extinguisher Dealer

Buckeye Fire Extinguisher Dealer

Georgia Association of Fire Safety Equipment Dealers

DON'T HESITATE TO CONTACT US
Scroll to Top